Error message
Warning: Array to string conversion in Drupal\deltalabdata\Controller\AgrupacioController->showDetails() (line 149 of modules/custom/deltalabdata/src/Controller/AgrupacioController.php).
Drupal\deltalabdata\Controller\AgrupacioController->showDetails() call_user_func_array() (Line: 123) Drupal\Core\EventSubscriber\EarlyRenderingControllerWrapperSubscriber->Drupal\Core\EventSubscriber\{closure}() (Line: 638) Drupal\Core\Render\Renderer->executeInRenderContext() (Line: 121) Drupal\Core\EventSubscriber\EarlyRenderingControllerWrapperSubscriber->wrapControllerExecutionInRenderContext() (Line: 97) Drupal\Core\EventSubscriber\EarlyRenderingControllerWrapperSubscriber->Drupal\Core\EventSubscriber\{closure}() (Line: 181) Symfony\Component\HttpKernel\HttpKernel->handleRaw() (Line: 76) Symfony\Component\HttpKernel\HttpKernel->handle() (Line: 53) Drupal\Core\StackMiddleware\Session->handle() (Line: 48) Drupal\Core\StackMiddleware\KernelPreHandle->handle() (Line: 28) Drupal\Core\StackMiddleware\ContentLength->handle() (Line: 32) Drupal\big_pipe\StackMiddleware\ContentLength->handle() (Line: 201) Drupal\page_cache\StackMiddleware\PageCache->fetch() (Line: 138) Drupal\page_cache\StackMiddleware\PageCache->lookup() (Line: 87) Drupal\page_cache\StackMiddleware\PageCache->handle() (Line: 48) Drupal\Core\StackMiddleware\ReverseProxyMiddleware->handle() (Line: 51) Drupal\Core\StackMiddleware\NegotiationMiddleware->handle() (Line: 36) Drupal\Core\StackMiddleware\AjaxPageState->handle() (Line: 51) Drupal\Core\StackMiddleware\StackedHttpKernel->handle() (Line: 741) Drupal\Core\DrupalKernel->handle() (Line: 19)
Warning: Array to string conversion in Drupal\deltalabdata\Controller\AgrupacioController->showDetails() (line 149 of modules/custom/deltalabdata/src/Controller/AgrupacioController.php).
Drupal\deltalabdata\Controller\AgrupacioController->showDetails() call_user_func_array() (Line: 123) Drupal\Core\EventSubscriber\EarlyRenderingControllerWrapperSubscriber->Drupal\Core\EventSubscriber\{closure}() (Line: 638) Drupal\Core\Render\Renderer->executeInRenderContext() (Line: 121) Drupal\Core\EventSubscriber\EarlyRenderingControllerWrapperSubscriber->wrapControllerExecutionInRenderContext() (Line: 97) Drupal\Core\EventSubscriber\EarlyRenderingControllerWrapperSubscriber->Drupal\Core\EventSubscriber\{closure}() (Line: 181) Symfony\Component\HttpKernel\HttpKernel->handleRaw() (Line: 76) Symfony\Component\HttpKernel\HttpKernel->handle() (Line: 53) Drupal\Core\StackMiddleware\Session->handle() (Line: 48) Drupal\Core\StackMiddleware\KernelPreHandle->handle() (Line: 28) Drupal\Core\StackMiddleware\ContentLength->handle() (Line: 32) Drupal\big_pipe\StackMiddleware\ContentLength->handle() (Line: 201) Drupal\page_cache\StackMiddleware\PageCache->fetch() (Line: 138) Drupal\page_cache\StackMiddleware\PageCache->lookup() (Line: 87) Drupal\page_cache\StackMiddleware\PageCache->handle() (Line: 48) Drupal\Core\StackMiddleware\ReverseProxyMiddleware->handle() (Line: 51) Drupal\Core\StackMiddleware\NegotiationMiddleware->handle() (Line: 36) Drupal\Core\StackMiddleware\AjaxPageState->handle() (Line: 51) Drupal\Core\StackMiddleware\StackedHttpKernel->handle() (Line: 741) Drupal\Core\DrupalKernel->handle() (Line: 19)
Deltaswab range tube with ViCUM® medium and flocked swab
INTENDED USE - DESCRIPTION
- Tube with transport medium: Directive 98/79/EC.
- Medical devices for in vitro diagnostics
- Swab: Directive 93/42/EEC. Medical devices
The kit consists of:
- A tube with 2 ml of ViCUM® universal liquid transport medium.
- A flocked swab packaged in peel-pack.
- Presentation of the kit in plastic flow pack.
- Swab: sterile by radiation (R).
- Tube with medium: sterile by filtration.
ViCUM® is a universal liquid transport medium formulated with a solution of balanced salts, bovine serum albumin, HEPES buffer, antibiotics and antifungals and suitable preservatives, with a pH that allows the viability of viruses, Chlamydia, Mycoplasma and ureaplasma. Contains phenol red and includes antibiotics that inhibit the growth of bacteria and fungi, ensuring suitability in sample recovery. Each tube contains glass beads to facilitate cell lysis, sample homogeneity and maximize elution. Designed for cell culture, performing antigen studies for viral detection and genomic amplification techniques by PCR.
FEATURES AND ADVANTAGES OF THE DELTASWAB SYSTEM
FEATURES AND ADVANTAGES OF THE FLOCKED SWAB
INSTRUCTIONS FOR USE
- Compatible with the new sample inoculation and seeding automation equipment.
- Compatible with molecular diagnostic techniques.
- Facilitates the collection, transport and subsequent treatment of microbiological samples.
- Greater reliability in sample recovery: high absorption and elution capacity of the new Deltaswab flocked swab.
- Greater sample viability, since it remains completely suspended in the medium.
- Allows obtaining different homogeneous inocula from the same sample.
- Adapts to any work protocol.
- Minimises possible cross-contamination due to less handling and maximum tightness.
- Greater comfort for the user: conical bottom that facilitates shaking and greater stability of the skirted tube.
- Greater comfort for the patient thanks to the softer swab cover.
- Standardises the reception of samples in microbiology laboratories.
- Facilitates manual inoculation.
- Allows direct spreading on the slide, as it does not contain the agar medium.
- Ensures the correct transport and storage of samples both at room temperature (20 - 25 °C) and at refrigeration temperature (4 - 8 °C).
- Maximum reliability and practicality of the breaking point.
- Support made of polystyrene --> Optimal safety.
- Head in flocked polyester --> Greater absorption of the sample and elution of the same in the medium.
- Maximum adaptability, wide range.
- Maximum comfort: anatomical and ergonomic design.