4861000104 | 1 | Eppendorf Xplorer, 8 canales, 0,5-10µl, pulsador de báscula multifunción gris para puntas 20µl | 0,5 – 10 µL | 0.5 µL: ± 6%; ± 0.03 µL,1 µL: ± 3%; ± 0.03 µL,5 µL: ± 1.5%; ± 0.075 µL,10 µL: ± 0.8%; ± 0.08 µL | 0.01 µL | - | 0.5 µL: ± 10%; ± 0.05 µL,1 µL: ± 5%; ± 0.05 µL,5 µL: ± 3%; ± 0.15 µL,10 µL: ± 2%; ± 0.2 µL | grey | 8 |
4861000112 | - | Eppendorf Xplorer, 12 canales, 0,5-10µl, pulsador de báscula multifunción gris para puntas 20µl | 0,5 – 10 µL | 0.5 µL: ± 6%; ± 0.03 µL,1 µL: ± 3%; ± 0.03 µL,5 µL: ± 1.5%; ± 0.075 µL,10 µL: ± 0.8%; ± 0.08 µL | 0.01 µL | - | 0.5 µL: ± 10%; ± 0.05 µL,1 µL: ± 5%; ± 0.05 µL,5 µL: ± 3%; ± 0.15 µL,10 µL: ± 2%; ± 0.2 µL | grey | 12 |
4861000120 | - | Eppendorf Xplorer, 8 canales, 5-100µl, pulsador de báscula multifunción amarillo para puntas 200µl | 5 – 100 µL | 5 µL: ± 4%; ± 0.2 µL,10 µL: ± 2%; ± 0.2 µL,50 µL: ± 0.8%; ± 0.4 µL,100 µL: ± 0.25%; ± 0.25 µL | 0.1 µL | - | 5 µL: ± 6%; ± 0.3 µL,10 µL: ± 2%; ± 0.2 µL,50 µL: ± 1%; ± 0.5 µL,100 µL: ± 0.8%; ± 0.8 µL | yellow | 8 |
4861000139 | - | Eppendorf Xplorer, 12 canales, 5-100µl, pulsador de báscula multifunción amarillo para puntas 200µl | 5 – 100 µL | 5 µL: ± 4%; ± 0.2 µL,10 µL: ± 2%; ± 0.2 µL,50 µL: ± 0.8%; ± 0.4 µL,100 µL: ± 0.25%; ± 0.25 µL | 0.1 µL | - | 5 µL: ± 6%; ± 0.3 µL,10 µL: ± 2%; ± 0.2 µL,50 µL: ± 1%; ± 0.5 µL,100 µL: ± 0.8%; ± 0.8 µL | yellow | 12 |
4861000147 | - | Eppendorf Xplorer, 8 canales, 15-300µl, pulsador de báscula multifunción naranja para puntas 300µl | 15 – 300 µL | 15 µL: ± 2%; ± 0.3 µL,30 µL: ± 1%; ± 0.3 µL,150 µL: ± 0%; ± 0.75 µL,300 µL: ± 0.25%; ± 0.75 µL | 0.2 µL | - | 15 µL: ± 6%; ± 0.9 µL,30 µL: ± 2.5%; ± 0.75 µL,150 µL: ± 1%; ± 1.5 µL,300 µL: ± 0.6%; ± 1.8 µL | orange | 8 |
4861000155 | - | Eppendorf Xplorer, 12 canales, 15-300µl, pulsador de báscula multifunción naranja para puntas 300µl | 15 – 300 µL | 15 µL: ± 2%; ± 0.3 µL,30 µL: ± 1%; ± 0.3 µL,150 µL: ± 0%; ± 0.75 µL,300 µL: ± 0.25%; ± 0.75 µL | 0.2 µL | - | 15 µL: ± 6%; ± 0.9 µL,30 µL: ± 2.5%; ± 0.75 µL,150 µL: ± 1%; ± 1.5 µL,300 µL: ± 0.6%; ± 1.8 µL | orange | 12 |
4861000163 | - | Eppendorf Xplorer, 8 canales, 50-1200µl, pulsador de báscula multifunción verde para puntas 1250µl | 50 – 1.200 µL | 50 µL: ± 1.2%; ± 0.6 µL,120 µL: ± 0.9%; ± 1.08 µL,600 µL: ± 0.4%; ± 2.4 µL,1200 µL: ± 0.3%; ± 3.6 µL | 1 µL | - | 50 µL: ± 8%; ± 4 µL,120 µL: ± 6%; ± 7.2 µL,600 µL: ± 2.7%; ± 16.2 µL,1200 µL: ± 1.2%; ± 14.4 µL | green | 8 |
4861000171 | - | Eppendorf Xplorer, 12-canales, 50-1200 µL, pulsador de báscula multifunción verde para puntas 1250 µL | 50 – 1.200 µL | 50 µL: ± 1.2%; ± 0.6 µL,120 µL: ± 0.9%; ± 1.08 µL,600 µL: ± 0.4%; ± 2.4 µL,1200 µL: ± 0.3%; ± 3.6 µL | 1 µL | - | 50 µL: ± 8%; ± 4 µL,120 µL: ± 6%; ± 7.2 µL,600 µL: ± 2.7%; ± 16.2 µL,1200 µL: ± 1.2%; ± 14.4 µL | green | 12 |
4861000767 | - | Eppendorf Xplorer plus, 8- canales, 0,5-10 µL, pulsador de báscula multifunción gris para puntas 20 µL | 0,5 – 10 µL | 0.5 µL: ± 6%; ± 0.03 µL,1 µL: ± 3%; ± 0.03 µL,5 µL: ± 1.5%; ± 0.075 µL,10 µL: ± 0.8%; ± 0.08 µL | 0.01 µL | - | 0.5 µL: ± 10%; ± 0.05 µL,1 µL: ± 5%; ± 0.05 µL,5 µL: ± 3%; ± 0.15 µL,10 µL: ± 2%; ± 0.2 µL | grey | 8 |
4861000775 | - | Eppendorf Xplorer plus, 12- canales, 0,5-10 µL, pulsador de báscula multifunción gris para puntas 20 µL | 0,5 – 10 µL | 0.5 µL: ± 6%; ± 0.03 µL,1 µL: ± 3%; ± 0.03 µL,5 µL: ± 1.5%; ± 0.075 µL,10 µL: ± 0.8%; ± 0.08 µL | 0.01 µL | - | 0.5 µL: ± 10%; ± 0.05 µL,1 µL: ± 5%; ± 0.05 µL,5 µL: ± 3%; ± 0.15 µL,10 µL: ± 2%; ± 0.2 µL | grey | 12 |
4861000778 | - | Eppendorf Xplorer® plus, 16 canales, variable, 1 – 20 µL, rosa pálido | 1 – 20 µL | 1 µL: ± 8%; ± 0.08 µL,2 µL: ± 5%; ± 0.1 µL,10 µL: ± 2%; ± 0.2 µL,20 µL: ± 1%; ± 0.2 µL | 0.02 µL | variable | 1 µL: ± 12%; ± 0.12 µL,2 µL: ± 8%; ± 0.16 µL,10 µL: ± 4%; ± 0.4 µL,20 µL: ± 2%; ± 0.4 µL | pale pink | 16 |
4861000779 | - | Eppendorf Xplorer® plus, 24 canales, variable, 1 – 20 µL, rosa pálido | 1 – 20 µL | 1 µL: ± 8%; ± 0.08 µL,2 µL: ± 5%; ± 0.1 µL,10 µL: ± 2%; ± 0.2 µL,20 µL: ± 1%; ± 0.2 µL | 0.02 µL | variable | 1 µL: ± 12%; ± 0.12 µL,2 µL: ± 8%; ± 0.16 µL,10 µL: ± 4%; ± 0.4 µL,20 µL: ± 2%; ± 0.4 µL | pale pink | 24 |
4861000783 | - | Eppendorf Xplorer plus, 8- canales, 5-100 µL, pulsador de báscula multifunción amarillo para puntas 200 µL | 5 – 100 µL | 5 µL: ± 4%; ± 0.2 µL,10 µL: ± 2%; ± 0.2 µL,50 µL: ± 0.8%; ± 0.4 µL,100 µL: ± 0.25%; ± 0.25 µL | 0.1 µL | - | 5 µL: ± 6%; ± 0.3 µL,10 µL: ± 2%; ± 0.2 µL,50 µL: ± 1%; ± 0.5 µL,100 µL: ± 0.8%; ± 0.8 µL | yellow | 8 |
4861000791 | - | Eppendorf Xplorer plus, 12- canales, 5-100 µL, pulsador de báscula multifunción amarillo para puntas 200 µL | 5 – 100 µL | 5 µL: ± 4%; ± 0.2 µL,10 µL: ± 2%; ± 0.2 µL,50 µL: ± 0.8%; ± 0.4 µL,100 µL: ± 0.25%; ± 0.25 µL | 0.1 µL | - | 5 µL: ± 6%; ± 0.3 µL,10 µL: ± 2%; ± 0.2 µL,50 µL: ± 1%; ± 0.5 µL,100 µL: ± 0.8%; ± 0.8 µL | yellow | 12 |
4861000792 | - | Eppendorf Xplorer® plus, 16 canales, variable, 5 – 100 µL, amarillo claro | 5 – 100 µL | 5 µL: ± 4%; ± 0.2 µL,10 µL: ± 2%; ± 0.2 µL,50 µL: ± 0.8%; ± 0.4 µL,100 µL: ± 0.25%; ± 0.25 µL | 0.1 µL | variable | 5 µL: ± 6%; ± 0.3 µL,10 µL: ± 2%; ± 0.2 µL,50 µL: ± 1%; ± 0.5 µL,100 µL: ± 0.8%; ± 0.8 µL | light yellow | 16 |
4861000793 | - | Eppendorf Xplorer® plus, 24 canales, variable, 5 – 100 µL, amarillo claro | 5 – 100 µL | 5 µL: ± 4%; ± 0.2 µL,10 µL: ± 2%; ± 0.2 µL,50 µL: ± 0.8%; ± 0.4 µL,100 µL: ± 0.25%; ± 0.25 µL | 0.1 µL | variable | 5 µL: ± 6%; ± 0.3 µL,10 µL: ± 2%; ± 0.2 µL,50 µL: ± 1%; ± 0.5 µL,100 µL: ± 0.8%; ± 0.8 µL | light yellow | 24 |
4861000805 | - | Eppendorf Xplorer plus, 8- canales, 15-300 µL, pulsador de báscula multifunción naranja para puntas 300 µL | 15 – 300 µL | 15 µL: ± 2%; ± 0.3 µL,30 µL: ± 1%; ± 0.3 µL,150 µL: ± 0.5%; ± 0.75 µL,300 µL: ± 0.25%; ± 0.75 µL | 0.2 µL | - | 15 µL: ± 6%; ± 0.9 µL,30 µL: ± 2.5%; ± 0.75 µL,150 µL: ± 1%; ± 1.5 µL,300 µL: ± 0.6%; ± 1.8 µL | orange | 8 |
4861000813 | - | Eppendorf Xplorer plus, 12- canales, 15-300 µL, pulsador de báscula multifunción naranja para puntas 300 µL | 15 – 300 µL | 15 µL: ± 2%; ± 0.3 µL,30 µL: ± 1%; ± 0.3 µL,150 µL: ± 0.5%; ± 0.75 µL,300 µL: ± 0.25%; ± 0.75 µL | 0.2 µL | - | 15 µL: ± 6%; ± 0.9 µL,30 µL: ± 2.5%; ± 0.75 µL,150 µL: ± 1%; ± 1.5 µL,300 µL: ± 0.6%; ± 1.8 µL | orange | 12 |
4861000821 | - | Eppendorf Xplorer plus, 8- canales, 50-1200 µL, pulsador de báscula multifunción verde para puntas 1250 µL | 50 – 1.200 µL | 50 µL: ± 1.2%; ± 0.6 µL,120 µL: ± 0.9%; ± 1.08 µL,600 µL: ± 0.4%; ± 2.4 µL,1200 µL: ± 0.3%; ± 3.6 µL | 1 µL | - | 50 µL: ± 8%; ± 4 µL,120 µL: ± 6%; ± 7.2 µL,600 µL: ± 2.7%; ± 16.2 µL,1200 µL: ± 1.2%; ± 14.4 µL | green | 8 |
4861000830 | - | Eppendorf Xplorer plus, 12- canales, 50-1200 µL, pulsador de báscula multifunción verde para puntas 1250 µL | 50 – 1.200 µL | 50 µL: ± 1.2%; ± 0.6 µL,120 µL: ± 0.9%; ± 1.08 µL,600 µL: ± 0.4%; ± 2.4 µL,1200 µL: ± 0.3%; ± 3.6 µL | 1 µL | - | 50 µL: ± 8%; ± 4 µL,120 µL: ± 6%; ± 7.2 µL,600 µL: ± 2.7%; ± 16.2 µL,1200 µL: ± 1.2%; ± 14.4 µL | green | 12 |